This site uses cookies to measure how you use the website so it can be updated and improved based on your needs and also uses cookies to help remember the notifications you’ve seen, like this one, so that we don’t show them to you again. If you could also tell us a little bit about yourself, this information will help us understand how we can support you better and make this site even easier for you to use and navigate.

Comparison of two analytical platforms for the clinical qualification of Alzheimer’s disease biomarkers in pathologically-confirmed dementia

Authors

Le Bastard, Nathalie, Coart, Els, Vanderstichele, Hugo, Vanmechelen, Eugeen, Martin, Jean-Jacques, Engelborghs, Sebastiaan

Journal

Journal Of Alzheimer's Disease: JAD, Volume: 33, No.: 1, Pages.: 117-131

Year of Publication

2013

Abstract

Combined analysis of the Alzheimer’s disease (AD) biomarkers amyloid-β(1-42) (Aβ(1-42)), total tau (T-tau), and hyperphosphorylated tau (P-tau(181P)) in cerebrospinal fluid (CSF) reduces the uncertainty associated with clinical dementia diagnosis. The present study evaluated the diagnostic accuracy of the CSF biomarker concentrations obtained with a multi-analyte Luminex assay (INNO-BIA AlzBio3) in comparison to single-analyte ELISA tests (INNOTEST). Data from 66 pathologically-confirmed dementia patients (51 AD and 15 non-AD) and 95 controls were included. Cut-off values were determined for each individual biomarker determined using both methods for different diagnostic challenges (dementia-controls; AD-controls; AD-non-AD). Comparing the diagnostic accuracy of individual cut-off values between INNO-BIA and INNOTEST, no relevant differences could be identified. Logistic regression was used in addition to identify the best combination of predictor variables (biomarkers). Discrimination of dementia patients from controls using Aβ(1-42) and T-tau yielded a diagnostic accuracy of 0.87 and 0.90 for INNO-BIA and INNOTEST, respectively. Discriminating AD patients from controls, the diagnostic accuracy was 0.90 and 0.93 for INNO-BIA and INNOTEST, respectively. Optimal discrimination of AD and non-AD patients was achieved by combining Aβ(1-42) and P-tau(181P) (diagnostic accuracy = 0.86). In conclusion, which AD biomarkers or combination thereof are most informative is dependent on the differential diagnosis, but the clinical value of these markers in each of the differential diagnoses is independent of the method by which concentrations are determined. Since the clinical value of the ELISA (INNOTEST) and Luminex (INNO-BIA) tests is comparable, further research to select the most suitable analytical platform for routine CSF biomarker measurements is needed.;

Keywords

adolescent, adult, aged, aged, 80 and over, alzheimer disease, biological markers, cerebrospinal fluid, dementia, diagnosis, enzymelinked immunosorbent assay, female, humans, luminescent measurements, male, methods, middle aged, pathology, peptide fragments, tau proteins, young adult

Countries of Study

Belgium

Types of Dementia

Alzheimer’s Disease

Types of Study

Non randomised controlled trial

Type of Outcomes

Other

Type of Interventions

Diagnostic Target Identification

Diagnostic Targets

Biological Testing